Humidifier by Plus Minus Zero V.2 PDF Print E-mail

Plus Minus Zero Humidifier is a steam based humidifying system and may create minor sounds of steam generation.

1. Warnings and Cautions for using the unit
2. Parts Name
3. Operating the humidifier
4. Maintenance Instruction

 

1. Warnings and Cautions for using the unit

Do not use the unit if you notice a water leak or burning smell. Do not use any visibly damaged parts or products.

warning_03

All maintenance must be done after unplugging the unit from the power source. Make sure that the wall power plug is disconnected.

Do not open or disasemble the unit, manufacturer or we will not be liable for any results.

warning_02

Do not apply water directly to the main unit.  Dry your hand completely before any operation.The magnetic plus has a magnet inside so the metal parts such as paper clips, sewing needles may be caused to the plus, please do check before using it.

warning_05

Do not place face, hands or any other thinkgs directly above or closed to the steam outlet on the top. Keep baby and children away from the unit. 

Wait until unit is cooled off before moving or doing any maintenance to the unit. Keep pwer cable disconnected from the wall and the unit if youdo not use the unit.

warning_01

Tilt the unit so the water goes out in the direction of the arrow mark when draining the water from the main unit.

Do not use the unit near the electric appliences may sensitive to moist or steam.

Use clean water/filtered water for the best result for operation and maintenance. Do not mix anything in the water.

2. Parts Name

A.Watertank placement registration mark on the watertank
B. Steam Outlet
C. Watertank registration mark on the main unit
D. Hood Handle
E. Hood
F. Inner Gsket
G. Outer Gasket


H. Water Filter ( Use 2 filters at a time.)
I. Air Vent
J. Heating Unit (HOT)
K. Water Level Sensor
L. Direction for draining water

M. Power Plug
N. Power Cable
O. Magnetic Plug
P. Water Level Monitor Window
Q. Water Input
R. Water Tank Handle

S. Operation LED Monitor
T. Operation Mode Selector
U. Air Filter
V. Magnetic Plus Input
W. Funnel for water tank
X. Aroma Pot


3. Operating the humidifier

Removing watertankUse both hands to lift up the watertank unit. Excess water may drop from the watertank if there is any.
Flip the watertank upside down and you can lift the handle to up.

Remove the watertank cap to fill the water. Use the funnel provided with the unit to fill the watertank so the water touches the water level line on the water level line.

Close the watertank cap and remove all excess water from the unit and watertank.

When the operation mode selector is set to "AUTO" the unit stops the operating when the humididy of the air reached 60%. In another mode the unit operates until water runs out. This should be set to the "MANUAL" position as default.

Use Hood Handle to open the Hood and place 2 water filters inside before operating.
Plase the main unit on the leveled and stable place and place the watertank.
You should be looking the Watertank Registration Mark on both watertank and the main units and match it while lowering the watertank to be seated perfectly.

Connect the magnetic plug before connecting the power cable to the power outlet on the wall. Do not power the unit when the unit is on the unleveled surface.
Connect the magnetic plug first and power plug to wall outlet.
The unit should start with a two short indicating sound.

When water runs out or too much water has entered to the watertank, the unit indicates with a five short sound. Heater stops immediately and the air fan stops in 5 minuts.

Disconnect the power plug from the wall outlet first and disconnect the magnetic plug form the unit.

4. Maintenance Instruction

Heating uit needs to be maintenanced once or twice a week.

Air fileter needs to be dried after cleaning.

maintenance_01

Tilt the unit so the water goes out in the direction of the arrow mark when draining the water from the main unit.

maintenance_02

 

  Water filter needs to be cleaned.

maintenance_03

 
< Prev   Next >
Product Search

Look!
NEO FX Eye Drop
NEO FX Eye Drop
$ 14.50
Add to Cart


iBud Retractable Earphone
iBud Retractable Earphone
$ 11.56
Add to Cart


Dino-Lite Stand
Dino-Lite Stand
$ 99.20
Add to Cart


ButterFly FMP3 Player 1GB
ButterFly FMP3 Player 1GB
$ 139.36
Add to Cart


Tenugui-Hon
Tenugui-Hon
$ 15.50
Add to Cart


RSS Feed
Add to MyYahoo!
Subscribe in NewsGator Online
Add to Newsburst
Add to Google
Add to My AOL
Add to Pluck
Subscribe in FeedLounge
Add to Windows Live
Add to NetVibes
Subscribe in Rojo
Subscribe in Bloglines
Add to MyMSN
Add to Plusmo for your cellphone
Add to PageFlakes
Add to Technorati
Add to BlinkBits
top of page

        

© 2008 Compact Impact